Non-invasive biomarkers for detecting progression toward hypovolemic cardiovascular instability in a lower body negative pressure model

Non-invasive biomarkers for detecting progression toward hypovolemic cardiovascular instability in a lower body negative pressure model

Occult hemorrhages after trauma can be present insidiously, and if not detected early enough can result in patient death. This study evaluated a hemorrhage model on 18 human subjects, comparing the performance of traditional vital signs to multiple off-the-shelf non-invasive biomarkers. A validated lower body negative pressure (LBNP) model was used to induce progression towards hypovolemic cardiovascular instability. Traditional vital signs included mean arterial pressure (MAP), electrocardiography (ECG), plethysmography (Pleth), and the test systems utilized electrical impedance via commercial electrical impedance tomography (EIT) and multifrequency electrical impedance spectroscopy (EIS) devices. Absolute and relative metrics were used to evaluate the performance in addition to machine learning-based modeling. Relative EIT-based metrics measured on the thorax outperformed vital sign metrics (MAP, ECG, and Pleth) achieving an area-under-the-curve (AUC) of 0.99 (CI 0.95–1.00, 100% sensitivity, 87.5% specificity) at the smallest LBNP change (0–15 mmHg). The best vital sign metric (MAP) at this LBNP change yielded an AUC of 0.6 (CI 0.38–0.79, 100% sensitivity, 25% specificity). Out-of-sample predictive performance from machine learning models were strong, especially when combining signals from multiple technologies simultaneously. EIT, alone or in machine learning-based combination, appears promising as a technology for early detection of progression toward hemodynamic instability.

 

figure 1      figure 2      figure 3

 

figure 4  figure 5  figure 6

 

 

Learn more about Medical Research ISX-3

Non-invasive biomarkers for detecting progression toward hypovolemic cardiovascular instability in a lower body negative pressure model
Medical Research ISX-3 with a Multiplexer

Get to know the Medical Research ISX-3

Latest Products

  • Sciospec EIT-lung imaging kit for impedance tomography
    LungEIT Kit

    The Sciospec LungEIT Kit is your turn-key, easy entry into lung imaging with impedance tomography.

    Learn more
  • Sciospec LCR-1
    LCR Meter
    0.00

    powerful, yet easy to use LCR meter

    Learn more
  • Medical Research ISX-3
    0.00

    scalable impedance analyzer with medical grade safety features

    Learn more

Get in touch with us

+49 3425 88399 00

info@www.sciospec.com

Sciospec Scientific Instruments GmbH
Leipziger Str. 43b, 04828 Bennewitz, Germany